10 / 107
DEGSON DG136T-10.16 PCB UNIVERSAL SCREW TERMINAL BLOCK
DEGSON DG136T-10.16 PCB UNIVERSAL SCREW TERMINAL BLOCK PCB Spring Terminal Blocks Terminal Blocks Degson Singapore Distributor, Supplier, Supply, Supplies | Mobicon-Remote Electronic Pte Ltd
Quantity
Item Data  
APPROVAL
Test standard IEC/ EN60998-1£º2004 / UL1059
Pitch                                      [mm] 10.16
Poles 02-XXP
EN60998  Test data VDE certificate NO. 40028234
Rated voltage                             [V] 1000
Rated current                              [A] 65
Rated connection capacity(solid/stranded) [mm2] 2.5~16.0
Surge voltage category/pollution degree/material group III/2/I
Withstanding Voltage                  [KV/min] 3
Rated torque                               [N.m] 1.2
UL1059Test data UL File Number E228872
Use group B C D
Rated voltage                             [V] 300 300 300
Rated current                             [A] 60 60 10
Rated connection capacity 20~6
(solid/stranded) [AWG]
Rated torque                        [Lb. in] 15
General data /
Screw M4
Inflammability classUL94 V-0
Ambient temperature                       [¡æ] -40~+105
Relative humidity 5%-95%
Inspection standard MIL-STD-105E II
AQL 0.65
Warranty 12 months
Material and plating /
Housing PA66
Screws Steel£¬Zn plated
Contact Copper alloy£¬Sn plated
Cage Copper alloy£¬Ni plated
Wire connecting
Recommended stripping length 10-11mm;
For solid wire, stripping wire to the appointed length, then tightening with rated torque.
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.