DEGSON - DE-010-M
Quantity
Item Data
Inserts MatchingD10B Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
¼«Êý(Poles) 10P+PE
The need for additional or dering crimp contacts No
EN61984 Test data /
Rated voltage [V] 500
Rated current [A] 16
pollution degree 3
Rated impulse voltage [KV] 6
Insulation resistance ≥1010Ω
UL/CSARated current ¡¡¡¡¡¡¡¡¡¡ [V] 600
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature) [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts
Material Copper alloy
Surface Hard-silver plated
Contact resistance ≤1mΩ
Terminal Screw terminal
Rated torque [N·m] 0.5
Rated connection capacity(solid/stranded) 1.0-2.5mm² AWG18-14)
Screw Steel£¬Ni plated
Wire connecting
Recommended stripping length7-9mm;
For solid wire, stripping wire to the appointed length, then tightening with rated torque.
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.